- Contact Person : Mr. Xiao Jason
- Company Name : Guangzhou Blueswift Electric Co., Ltd.
- Tel : 86-20-39119708
- Fax : 86-20-39119628
- Address : Guangdong,Guangzhou,Room 201 Xianliedong Road 186-188, Tianhe District, Guangzhou City
- Country/Region : China
- Zip : 510075
Current Panel Meter
ApplicationPanel meter is one kind of electric measure indicator with the direct effection of imitative display. It is suitable for AC & DC output and input distribution circuit, power plant console cabinet, power operating board and different apparatus. It is used to measure DC current, voltage & AC current, voltage, frequency and phase power.
BLUESWIFT panel meter can measure the current, voltage frequency, active and reactive power, power factor in assembly equipment electrical cubes, boxes and other measurement system in industrial enterprise, chemical, metallurgy and electric textile.
1. Accuracy of current and voltage: class 1.5, accuracy of frequency, power and power factor: class 2.5, accuracy of ANNAI 48-A.V: class 2.5 2. Operation conditions: working temperature-25C~+40C, relative atmosphere humidity 85%.A few sands are allowable in the air 3. Outside mechanical applied force withstand: common type 4. Insulation strength Arcsine 50Hz, 2kV/2min. There should be no feed-through and flashover indications on the meter after the voltage tests 5. Working position: it should be mounted vertically to operate 6. Construction characters: the series meters can be divided into two types of construction, BLUESWIFT series,ampere, voltage meters are electromagnetic series adopting repulsive construction. When meter in AC circuit, the coil can bring out a magnet field. The stable and movable iron chip repels each other because of magnet and makes the pointer rotor turn till 4 the reverse torque equality ANNAI series frequency active reactive power, power factor meter are adjustable current type. The construction is made of electromagnetic measurement mechanism and electronic transfer .automobile, generator, handling of foul water, fire control, safe control and teaching instrument
Name | precision | normal specification | remark | |||
AC ammeter | A | 1.5 | 0.5-50A | can be directly connected | ||
A | 1.5 | 10/5A-800/5A |
| |||
KA | 1.5 | 1KA-10KA |
| |||
AC voltmeter | V | 1.5 | 10V-600V | can be directly connected | ||
KV | 1.5 | 1KV-35KV | 100V secondary voltage passed by voltage transformer | |||
DC ammeter | µA mA | 2.5 | 50μA-500μA 1mA-500mA |
| ||
A | 1.5 | 1A-15A | can be directly connected | |||
A | 1.5 | 15A-750A | outer attached shunt 75mV 60mV 50mV | |||
KA | 1.5 | 1KA-3KA | outer attached shunt 75mV 60mV 50mV | |||
DC voltmeter | V | 1.5 | 3V-600V | can be directly connected | ||
KV | 1.5 | 1KV-3KV | outer attached resistance value | |||
Hz meter | Hz | 2.5 | 45-55HZ 55-65HZ | 36V.100V.127V.220V.380V | ||
Power meter | KW.VAR | 2.5 | 100V 380V 380-380KV | 100V secondary voltage passed by voltage ; Secondary current passed by current transformer 5-10KA/5A | ||
cosφ meter | cosφ | 2.5 | COSφ =0.5-1-0.5 | 100V/5A 220V/5A 380V/5A | ||
Three-phase synchronous table | S | 2.5 | 100V,220V,380/100V |
Current Panel Meter